Addressable Fire Alarm System |
A Fire Alarm System is designed to detect the presence of fire by monitoring the environmental changes and to provide an early warning of fire that will notify people to evacuate and take action to stop the fire. Airlight’s addressable intelligent fire alarm systems respond rapidly to incipient fire signatures with unmatched precision maximizing speed, stability and reliability.

In an addressable system, devices are wired in a loop around the building with each device having its own unique 'address'. The system may contain one or more loops depending upon the size of the system and design requirements. Airlight’s one cable addressable fire alarm system works on 24 volts DC which is drawn from main control panel through a single cable (2 core). In case of a fire, initiating devices to panel and panel to Sounder beacon digital signals are sent through the same cable using power line communication technique. This system can also be seamlessly integrated with AHU, AC supply, Access Control system, BMS, etc.
In case of fire, the respective area detector senses the fire and sends the data of fire and initiating device’s address to the control panel. On receipt of the signal, the control panel display shows the exact zone number, zone location, device number and device location. The panel also sends signal to respective Sounder beacon (to give audible & visual alarm), fire fighting systems, HVAC tripping etc.
|
|
|
|
|
| Single Loop Intelligent Addressable Fire Alarm Panel - ALAWFP100 |
Designed to provide origin of fire indication triggered by addressable detector/MCP, and to trigger
designated sounder beacons to alert/evacuate the occupants, also to trip AHU, AC supply, etc. This unit is
fully addressable and it pin-points the exact location of fire for whose indication LCD display is provided. In
addition to the LCD 16 zonal back-up LEDs are present. The unit is powered by 230V AC and for backup built-
in SMF battery & battery charger is provided. This unit can be connected to 127 addressable devices. The
panel can be connected to PC for programming and can be integrated with graphics software. The panel
enclosure is made of Cold Rolled Sheet and it is aesthetic, sleek, compact to position as front office products.
|
|
|
|
Two Loop Intelligent Addressable Fire Alarm Panel - ALAMP702 |
Designed to provide origin of fire indication triggered by addressable detector/MCP, and to trigger
designated sounder beacons to alert/evacuate the occupants, also to trip AHU, AC supply, etc. This unit is
fully addressable and it pin-points the exact location of fire for whose indication LCD display is provided. In
addition to the LCD 16 zonal back-up LEDs are present. The unit is powered by 230V AC and for backup builtin
SMF battery & battery charger is provided. This unit can be connected to two loops of 127 addressable
devices. The panel can be connected to PC for programming and can be integrated with graphics
software. The panel enclosure is made of Cold Rolled Sheet and it is aesthetic, sleek, compact to position as front office products.
|
|
|
|
Addressable Intelligent Repeater Panel - ALARP701 |
Designed to provide a cost-effective platform for a fire alarm system annunciation; duplicating the same
information as the main control panel, but at a remote location. The panel offers system designers and end
users a technically sophisticated range of facilities and functions whilst maintaining ease of programming,
installation, and operation. The repeater panel has same lamps and text display as the main control panel
but no device circuits can be connected. The ALARP701 is a new force in high level annunciation for a wide
range of premises/systems.
|
|
|
|
Addressable Intelligent Optical Smoke Detector - ALASD701 |
Designed to provide the level smoke caused by fire as analogue value along with its address to an on-board memory. Control panel Collects these data in regular intervals for central processing. The detector's on-board processor also process the analogue value and provides alarm flag when the analogue value crosses the preset as fire Preset values of alarm flag and device address can be altered by the user from control panel.
|
|
|
|
Addressable Intelligent Heat Detector - ALAHD701 |
Designed to provide accurate amblent temperature data to control panel along with its address. The detector delivers the function of fire detection by measuring thermal levels caused by a fire and sets the alarm flag at on-board memory of the detector. Control panel collects these data in regular inerval for central processing. The detector canset alarm flag by fixed temperature and rate-of- rise temperature. Fixed temperature sensitivity can be altered from the panel of Addressable heat detector. The accurate tempeature level indication of all the area will be highly useful during fire emergencies for evacuation and other action paln. The system can be connected with PC graphics software making it user friendly. This multi-purpose intelligent
detector extends its use in various BMS applications, like HVAC monitoring, control, electric of
power management, etc.
|
|
|
|
Addressable Intelligent MultiSensor - ALAMD701 |
Designed to provide level of smoke and accurate temperature existing in the ambient air along with its address. These analogue values are stored at on-board memory of the detector. The detector delivers the function of fire detection by measuring thermal levels caused by a fire and sets the alarm flag at on-board memory of the detector. Control panel collects these data in regular interval for central processing. The detector can set alarm flag by fixed temperature and rate-of-rise temperature. Fixed temperature sensitivity
can be altered from the panel. The accurate temperature, smoke level indication of all the area will be highly useful during fire emergencies for evacuation and other action plan. The system can be connected with graphics
software making it user friendly. This multi-purpose intelligent detector extends its use in various
BMS applications, like HVAC monitoring, control, electrical\ power management, etc.
|
|
|
|
Addressable Manual Call Point - ALAMC701 |
Designed to provide manual alarm. In case of fire the person have to lift protective flip cover and press the glass. The momentary press sets the Alarm Flag in on-board memory. Control panel collects this Alarm data for
Central processing. The built-in LED indicator blinks in normal condition and glows when operated. Transparent,
strong & polycarbonate-made protective flip cover makes it double action to prevent accidental operation.
|
|
|
|
Addressable Loop Sounder Beacon - ALAHR701 |
Designed to be used in the same loop of detector cable for in-door use. It features an integral beacon within the sounder utilizing high intensity LED technology. The LED strobe fulfills the disability legislation. This unit’s appearance & size is like a regular detector making it possible to fit into regular detectors’ base. It is light-weight & can be fixed on false ceiling/wall. This intelligent sounder accepts & acts on various instruction from the control panel, like alert, evacuate, security, emergency, shift-bell, etc with various types of flash. The acoustic efficiency and sound distribution generates a wide angle good audibility in all directions.
|
|
|
|
Addressable Fault Isolator Module - ALASI701 |
Designed to be used in addressable system communication loop to create a segment. In practice, this unit is fixed every 20 to 25 devices; depending on site. It detects the short circuit and isolates the segment where short circuit exists enabling all other segment to work without interruption. This addressable unit also communicates the location of fault to the control panel for audio-visual indication. The unit checks the status every 5 seconds. If the fault is rectified automatically, it resets the segment back to operation.
|
|
|
|
Addressable Monitor Module - ALAMM701 |
Designed to monitor any volt-free switch contact, such as water-flow switch, sprinkler supervisory switch or relay output of an existing fire alarm panel. Depending on the configuration, a monitor module may
cause an alarm or fault signal at the panel. It also allows the wiring to the switch to be monitored for
open circuits, so triggering a fault indication at the panel. The ALAMM701 is installed directly onto the
loop wiring, carries a system address and enables signals from associated equipment to be
interfaced into the fire alarm system. Input signals are fully displayed at the control panel and can be programmed to activate
any system output.
|
|
|
| Addressable Control Module - ALACM701 |
Designed to provide single pole, volt free, change over contacts. The unit is intended for installation within the
equipment to be switched, thereby offering savings in installation costs when compared to long, auxiliary
circuit, wiring runs out from the control panel. Complying with standards, the relay can be located anywhere
on fire alarm circuit and is designed for power up or shut down of building services in fire conditions, for
example air conditioning plant. The unit is ideal for the control of associated system equipment such as door
release circuits, or the emergency shutdown of high risk services such as, gas or oil supply valves in boiler rooms.
|
|
|
|
Conventional Zone Interface Module - ALCAM701 |
Fully loop powered and enables existing or new conventional zones to be interfaced to an addressable system. Through its interface, each zone is assigned a unique address. Status conditions are reported as normal, open or alarm. The ALCAM601 uses state of the art technology and can be easily installed to satisfy demanding applications making the product universally acceptable.
|
|
|
| Addressable Weather Proof Manual Call Point - ALAMCW601 |
The unit is provided with pushbutton actuator with a mushroom head. The actuator is in contact with the glass cover, which when broken the internal contacts closes. When internal contact closes, built-in addressable
module sets the alarm flag in on-board memory. Control panel collects these data at regular intervals along
with its address for central processing. The panel then sends signal to respective sounders beacons to begin
evacuation. The unit is provided with a large gasket for weather protection.
|
|
|
| Addressable Flame Proof Manual Call Point - ALAMCF601 |
The unit is provided with push button actuator with a mushroom head. The actuator is in contact with the glass
cover, which when broken the internal contacts closes. When internal contact closes, built-in addressable
module sets the alarm flag in on-board memory. Control panel collects these data at regular intervals along
with its address for central processing. The panel then sends signal to respective sounders beacons to begin
evacuation. The unit is provided with a large gasket for weather protection.
|
|
|
| Airlight Graphics Software - ALGRS701 |
Designed to be integrated with fire alarm system to provide clear & precise real-time information of alarm on
PC work station with use of text, floor & map. The graphics software makes it easy for the user to locate
affected area to enable them to make efficient response to emergency by constantly monitoring incoming
alarm/trouble data. In case of alarm/trouble the particular floor plan will pop-up automatically and the
respective triggered device will flash with change of colour & will provide clear text message of zone no.,
device no. and description of device location. The software also has a password protection feature that allows only authorized personnel to login/logout/change password.
|
|
|
|