Latest News

Conventional Fire Alarm Panels
NAVEEN Microcontroller based Conventional Panel consumes very low current consumption and has builtin battery charger, space provision for SMF Battery, one man walk test, lamp test & zone isolation facility. Audio and visual indication for low Battery, Battery disconnect, AC fail,Charger fail and twin red LEDs for fire detection and single amber LED for fault indication.

Conventional Optical Smoke Detector - ALCSD701

Conventional Optical Smoke Detector is  a low profile plug-in device. The detection chamber in the detector consisting of an LED (light source)and a photo transistor (light sensor) combined with an integrated circuit provides quick and accurate detection of fire. When smoke enters the detection chamber across the path of light beam, the light is scattered by the smoke particles, directing it at the sensor. When the detector senses fire, it will switch into alarm condition with its LED glowing and hence dropping the line voltage. The control panel senses the change in voltage and triggers the appropriate alarm.

TECHNICAL SPECIFICATION
Operating Voltage 12 - 27V DC
Typical Standby Current 60 µA
Max. Alarm LED Current 40mA @ 24V
Operating Temperature -10°C to + 60°C
Humidty
0 to 95% RH (Non-condensing)
Wiring 2 Core
DIMENSIONS (EXCLUDING BASE)
Height 36 mm
Diameter 100 mm
Weight 70gm
Colour White
Material Polycarbonate
FEATURES:
Easy to install, low profile design
Common electronic free slide easy base for
optical, heat, multisensor, loop sounder, wireless
converter, etc.
Easy for maintenance
Remote LED option
Twin LED's Provide 360° Visibility
Built in Test Switch (By External magnet)
High Immunity To False Alarm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
Conventional Heat Detector - ALCHD701

Conventional Heat Detector is a device that responds to changes in ambient temperature using a sensing element (thermistor), which produces a change in electrical resistance in response to an increase in temperature. They are normally used in environments where smoke detector might generate false alarms (for example: kitchen). When the detector senses a rise in temperature, the line voltage drops. The control panel senses the change in voltage and activates the alarm if the temperature reaches threshold.

TECHNICAL SPECIFICATION
Operating Voltage 12 - 27V DC
Typical Standby Current 60 µA
Max. Alarm LED Current 40mA @ 24V
Operating Temperature -10°C to + 60°C
Humidty
0 to 95% RH (Non-condensing)
Wiring 2 Core
DIMENSIONS (EXCLUDING BASE)
Height 36 mm
Diameter 100 mm
Weight 70gm
Colour White
Material Polycarbonate
FEATURES:
Easy to install, low profile design
Common electronic free slide easy base for
optical, heat, multisensor, loop sounder, wireless
converter, etc.
Easy for maintenance
Remote LED option
Twin LED's Provide 360° Visibility
Built in Test Switch (By External magnet)
High Immunity To False Alarm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
Conventional Multisensor - ALCMD701

Conventional Multisensor is a low-profile plug-in device that responds to changes in ambient temperature and/or an increase in the level of smoke. It is a combination of both smoke & heat detector. The detection chamber in the detector consisting of an LED (light source) and a photo transistor (light sensor) combined with an integrated circuit provides quick and accurate detection of fire. When smoke enters the detection chamber across the path of light beam, the light is scattered by the smoke particles, directing it at the sensor. The thermal sensing element (thermistor), produces a change in electrical resistance in response to an increase in temperature. When the detector senses fire (as smoke or heat), it will switch into alarm condition                                                                 Lambda with its LED glowing and hence dropping the line voltage. The control panel senses the                                                                 change in voltage and triggers the appropriate alarm.

TECHNICAL SPECIFICATION
Operating Voltage 12 - 27V DC
Typical Standby Current 60 µA
Max. Alarm LED Current 40mA @ 24V
Operating Temperature -10°C to + 60°C
Humidty
0 to 95% RH (Non-condensing)
Wiring 2 Core
DIMENSIONS (EXCLUDING BASE)
Height 36 mm
Diameter 100 mm
Weight 70gm
Colour White
Material Polycarbonate
FEATURES:
Easy to install, low profile design
Common electronic free slide easy base for
optical, heat, multisensor, loop sounder, wireless
converter, etc.
Easy for maintenance
Remote LED option
Twin LED's Provide 360° Visibility
Built in Test Switch (By External magnet)
High Immunity To False Alarm

 

 

 

 

 

 

 

 

 

 

 

 

 
Conventional Manual Call Point - ALCMM701

Conventional Manual Call points Designed to trigger alarm manually. In case of fire, the person has to lift the protective flip cover and press the glass which activates the MCP’s internal micro-switch, thus dropping the line voltage. The control panel senses the change in voltage and activates the alarm. Transparent, strong, polycarbonate-made protective flip cover makes it double action to prevent accidental operation.

TECHNICAL SPECIFICATION
Operating Voltage 12 - 27V DC
Max. Alarm Currentnt 20 mA
Operating Temperature -10°C to + 60°C
Humidty
0 to 95% RH (Non-condensing)
Wiring 2 Core
DIMENSIONS (EXCLUDING BASE)
Height 99 mm
Breadth 99 mm
Depth 16 mm
Weight 230gm
Colour Red
Material ABS
FEATURES:
Easy to install, sleek, elegant design
Protective transparent flip cover to prevent
accidental activation
Dual-action operation as per standard
High Immunity To False Alarm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Conventional Sounder - ALCHP701

Conventional  Sounder is the device, Designed to provide audible & visual alarm to alert/evacuate in case of fire. It features an integral beacon within the sounder utilizing high intensity LED technology. The LED strobe fulfills the disability legislation. This unit’s appearance & size is like a regular detector making it possible to fit into regular detectors’ base. It is lightweight & can be fixed on false ceiling/wall. The acoustic efficiency and sound distribution generates a wide angle good audibility in all directions.

TECHNICAL SPECIFICATION
Operating Voltage 12 - 27V DC
Active Currentt 40 mA
Sound level 40mA @ 24V
Operating Temperature -10°C to + 60°C
Humidty
0 to 95% RH (Non-condensing)
Wiring 2 Core
DIMENSIONS (EXCLUDING BASE)
Height 40 mm
Diameter 100 mm
Weight 100gm
Colour Red
Material Polycarbonate
FEATURES:
Easy to install, sleek, low profile elegant design
Common electronic-free, slide easy base for
optical, heat, multisensor, loop sounder, etc
Low Current
Strobe provided by high intensity LED technology.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Auto Dialer - ALAD701

Conventional Auto Dialer Designed to be used with Fire Alarm & Security systems. The ALAD701 utilizes the latest speech dialer technology providing an advanced warning system which puts configuration, control and response at the fingertips of authorized users. Any trigger is communicated by voice message to pre-determined land-line or mobile phone numbers, enabling people to respond appropriately. Packed with advanced features yet straightforward to install and program, the ALAD701 is a new force in high level protection for a wide range of premises/systems.


Learn More        
Response Indicator - ALCRI701

Conventional Response Indicator Designed to be used as an auxiliary indication for detectors that are located in closed spaces (i.e., not Visible. For example: above false ceilings, in closed rooms, etc). Detectors are equipped with a terminal to allow connection to the Response Indicator. Response indicators contain a LED which lights up as soon as the connected detector detects fire.

TECHNICAL SPECIFICATION
Operating Voltage 16 - 24V DC
Active Current <1mA
Operating Temperature -10°C to + 60°C
Humidty
0 to 95% RH (Non-condensing)
Wiring 2 Core
DIMENSIONS (EXCLUDING BASE)
Height 17 mm
Diameter 70 mm
Weight 8 gm
Colour White
Material Polycarbonate
FEATURES:
Esthetically pleasing, modern, flat design
Screw-less connecting terminals
Easy to install
Compatible with all detectors

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Conventional Weather Proof Manual Call Point - ALCMCW601

Conventional Weather Proof Manual Call Point is provided with pushbutton actuator with a mushroom head. The actuator is in contact with the glass cover, which when broken the internal contacts closes. When internal contact closes, it will switch into alarm condition and hence dropping the line voltage. The control panel senses the change in voltage and sends signal to respective sounder beacons to begin evacuation. The unit is provided with a large gasket for weather protection.

TECHNICAL SPECIFICATION
Operating Voltage 15-24V DC
Max. Alarm Current 20 mA
Operating Temperature -10°C to + 60°C
Humidty
0 to 95% RH (Non-condensing)
Wiring 2 Core
MECHANICAL DATA
Material Aluminium LM6
Weight 1.5 Kg (Approx.,)
IP Protection IP 65
Finish Anti Corrosive epoxy powder coated
Cable Entry 2 x 3/4” ER
Gasket Neroprene
Hardware Stainless Steel (SS-304)
____________________________________
Type of protection WeatherProof - Exd
Area Classification Safe Area
Apparatus Standard IS - 13947 / 93
GA Drawing:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
Conventional Flame Proof Manual Call Point - ALCMCF601

Conventional Flame Proof Manual Call Point is provided with  pushbutton actuator with a mushroom head. The actuator is in contact with the glass cover, which when broken the internal contacts closes. When internal contact closes, it will switch into alarm condition and hence dropping the line voltage. The control panel senses the change in voltage and sends signal to respective sounder beacons to begin evacuation. The unit is provided with a large gasket for weather protection.

TECHNICAL SPECIFICATION
Operating Voltage 15-24V DC
Max. Alarm Current 20 mA
Operating Temperature -10°C to + 60°C
Humidty
0 to 95% RH (Non-condensing)
Wiring 2 Core
MECHANICAL DATA
Material Aluminium LM6
Weight 3.0 Kg (Approx.,)
IP Protection IP 65
Finish Anti Corrosive epoxy powder coated
Cable Entry 2 x 3/4” ER
Gasket Neroprene
Hardware Stainless Steel (SS-304)
____________________________________
Type of protection FlameProof - Exd
Area Classification Zone 1 & 2
Gas groups Group I,II A, II B
Apparatus Standard IS - 2148 / 81
GA Drawing: